Trouts
BASE SPECIFICATIONS OF THE SYSTEM
PRODUCTION OF THE FIRM: Stock farm of trouts
PLACE OF THE INSTALLATION: 12044 Centallo- Cn - Italy
TYPE OF THE WASTE: Trouts
QUANTITY: 650 Kg/day
CALORIFIC POWER: 1.500 kcal/kg
WORK TIME: HOURS- 8/day
DAYS- 6/week
WEEK- 50/year
INCINERATION POTENTIALITY: 80 kg/h
TYPE OF THE LOADING: Manual
TYPE OF THE COMBUSTION CHAMBER: Rotative
WORK TEMPERATURE: 770°C
AFTER-BURNER CHAMBER: Yes
WORK TEMPERATURE: 950 °C
GAS RESIDENCE TIME: 2 sec
HEAT RECOVERY: No
TYPE OF THE HEAT RECOVERY:
QUANTITY:
TREATMENT OF THE GAS: No
WORK CONTROL: Automatic
AUXILIARY COMBUSTIBILE: Fuel diesel
FUEL CONSUMPTION: 50 kg/h
|